Kinze KPM III Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento de jardinagem Kinze KPM III. Kinze KPM III User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
KPM III ELECTRONIC SEED MONITOR
OPERATOR
MANUAL
M0248 6/13
This manual is applicable to: KPM III Electronic Seed Monitor
Phase 3 Software
Record the serial numbers of your planter control system and the purchase date:
Planter Monitor Serial Number ___________________________________
Date Purchased _______________________________________________
Measured Pulses Per Mile/km
(Radar Distance Sensor) ________________________________________
Measured Pulses Per Mile/km
(Magnetic Distance Sensor) _____________________________________
Kinze
®
and the Kinze
®
logo are trademarks owned by Kinze Manufacturing, Inc.
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - OPERATOR

KPM III ELECTRONIC SEED MONITOROPERATOR MANUAL M0248 6/13This manual is applicable to: KPM III Electronic Seed Monitor

Página 2

StatusPlantAboutSetup ModeConfiguration:Effective row spacing: 15.0Front / Rear1. General Settings2. Seed Meter Settings3. Row Unit Alarm Levels4. Se

Página 3 - INTRODUCTION

ADDING INTERPLANT ROWS (REAR ROWS PREVIOUSLY PROGRAMMED ONLY)NOTE: Planter monitor configuration must contain

Página 4 - 2 6/13

SDS = Seed Delivery System There should be one sensorfor each Row and each Shaft.CancelKinze Planter ConfigurationPlanter Type Sensors Installe

Página 5

STEP 2 To conrm note below turn knob or use arrow keys to highlight “OK” button, then press knob or Enter key to conrm. If single Interplan

Página 6 - 4 6/13

STEP 2 Press F6 key next to Done. Display will return to Setup Mode screen.STEP 3 Turn knob or use arrow keys to highlight ‘‘8. Select Spee

Página 7

PROGRAMMING/CONNECTING SEED TUBES, SHAFT ROTATION SENSORS, AND/OR RADAR/MAGNETIC DISTANCE SENSORS NOTE: Sensor Setup screen automatically displays aft

Página 8 - 6 6/13

SPEED SENSOR CALIBRATION/PROGRAMMINGSTEP 1 Turn knob or use arrow keys to highlight ‘’10. Calibrate Speed Sensor” and press knob or Enter key. Dista

Página 9

When correct distance pulse count is known, calibration is not needed and the following steps may be used.STEP 1 Turn knob or use arrow keys

Página 10 - Monitor Operation

Acre Count Switch Kit STEP 1 With monitor OFF, attach an Acre Count Switch Kit to Muxbus connector, then turn monitor “ON”.STEP 2 Press F6 key unt

Página 11 - KPM IIIM0248

ENABLING/DISABLING INTERPLANT ROWSTo Enable or Disable InterplantSTEP 1 Return to “Planter Conguration” screen by pressing F2 key next to “Plant”.ST

Página 13

StartHelpDoneTEST MODETest mode report:Rear Row 1 0.00% 0 out of 0Rear Row 2 0.00% 0 out of 0Rear Row 3 0.00% 0 ou

Página 14 - 12 6/13

ROW SPACING• Press F2 key next to Spacing to display seed spacing keys. “Average Spacing” will appear in bottom L.H. corner of display.• Pr

Página 15

• Press F5 key next to Other for items available to display in bottom R.H. corner. Turn knob or use arrow keys to highlight “Sha

Página 16 - 14 6/13

WARNINGS AND ALARMSSTEP 1 Seed Rate Alarm - A seed rate alarm is activated whenever row average seed population drops below threshold set fo

Página 17

STEP 3 Counting Sensors Not Communicatining With Monitor - If monitor detects a communication error between sensor and monitor, monitor beeps twice.

Página 18 - 16 6/13

NOTE: Planter monitor configuration above has an even number of front (Interplant) rows (8).STEP 7 Sensor Present Warning – One or more sensors are pr

Página 19 - 30618 8.03

Enable Area Counter • Highlight desired ‘‘Area Counter’’ by turning rotary encoder knob or using arrow keys.• Press knob or Enter key. A “Conrm Area

Página 20 - 18 6/13

NOTE: If “Total area” is highlighted and F3 key next to Clear is pressed the following request for confirmation displays.Clear Area CounterTotal Area,

Página 21

STEP 4 Turn knob or use arrow keys to highlight faulty sensor and press F2 key next to Remove.STEP 5 The following message displays. Select OK to co

Página 22 - 20 6/13

NOTE: Refer to IS715 for installation instructions for your KPM III. The KPM III electronic seed monitor system consists of:• A tractor mounted KPM I

Página 23

ROTARY ENCODER KNOB• Turn knob clockwise to increase or counterclockwise to decrease value of item.• Turn knob clockwise to scroll up or countercloc

Página 24

CHANGING VOLUME, CONTRAST, AND BACKLIGHTING WITH AV KEYAlarm, volume, LCD screen contrast, and backlighting may be adjusted at any time, regardl

Página 25 - Setup Mode

STEP 3 Select ‘‘5. Congure Planter Monitor’’ by turning the knob or using the arrow keys. Press the knob or the Enter key to display the highlighted

Página 26 - Area Management

STEP 8 If applicable, turn knob or use arrow keys to advance to “Vacuum”. Press knob or Enter key and a drop down menu will appear. Select correct nu

Página 27

SEED METER SETTINGSSTEP 1 Scroll to ‘‘2. Seed Meter Settings” by turning rotary encoder knob or using arrow keys. Press knob or Enter key to display

Página 28

StatusPlantAboutSetup ModeConfiguration: Front / Rear1. General Settings2. Seed Meter Settings3. Row Unit Alarm Levels4. Setup Data Logging5. Configur

Comentários a estes Manuais

Sem comentários